Applied Chemistry for Engineering Vol.18 No.3 pp.239-244
DOI :

Research Papers : Methane Recovery and Carbon Dioxide Stripping by MEA Solution the Autocirculation Bubble Lift Column Reactor

In Hwa Lee

Abstract

For the simultaneous methane recovery and CO2-stripping, we have been developed dual vent auto circulation bubble lift column
reactor, and evaluate optimum conditions for monoethanolamine (MEA) solutions as a CO2 absorbent. At the 5 wt%
MEA solution, we investigated the pH change during CO2-stripping and absorption reaction, CO2-stripping rate with reaction
time, methane recovery efficiency for various inflow rates of air, CO2-stripping rate for flow liquid over flow height, and
CO2-stripping dependency on the temperature of absolvent solutions. The suggested optimum conditions for CO2 recovery
with MEA in the dual vent auto circulation bubble lift column reactor were 40 mm over flow liquid height, 1.5 L/min of
air inflow rate, and 25 ℃ of absorbent solution temperature.