ISSN : 1225-0112(Print)
ISSN : 2288-4505(Online)
ISSN : 2288-4505(Online)
Research Papers : Hydrodynamic Characteristics of a Square Internally Circulating Fluidized Bed for Sludge Combustion
Abstract
The effects of superficial gas velocities that lead to a draft tube and to an annulus section on solid circulation rate of the draft tube to the annulus section, as well as gas bypassing fractions, pressure drop across an orifice and gas holdup have been examined in a square internally circulating fluidized bed (0.28 m width, 2.6 m height) with a square draft tube of orifice-type (0.1 m width, 0.9 m height). At a given aeration rate to the annulus section to draft tube increased, and the gas bypassing fractions from draft tube to annulus section decreased with increasing gas velocities to the draft tube. At a given aeration rate to the draft tube, the solid circulation rate and pressure drop across the orifice increased, and the gas bypassing fractions remain constant with increasing gas velocities to the annulus section. The hydrodynamic characteristics of the square internally circulating fluidized bed were found to be similar to those of circular internally circulating fluidized beds.
연구논문 : 슬러지 연소용 사각 내부순환유동층 반응기의 수력학적 특성
초록
오리피스 타입의 draft tube (가로 0.1 m, 세로 0.1 m, 높이 0.9 m)를 갖는 사각 내부순환 유동층 반응기(가로 0.28 m, 세로 0.28 m, 높이 2.6m)에서 draft tube와 annulus section으로 주입되는 기체 유속(Ud, Ua)이 고체 입자의 순환 속도(Gs), gasbypassing fractions, 오리피스를 통한 압력강하(ΔPor) 및 기체 체류량(εd)에 미치는 영향을 연구하였다. Annulus section으로 주입되는 기체 유속이 일정한 경우, draft tube로 주입되는 기체유속을 증가시킴에 따라 고체 입자의 순환 속도, 오리피스를 통한 압력강하 및 annulus section에서 draft tube로의 gas bypassing fractions는 증가하였고, draft tube에서 annulus section으로의 gas bypassing fractions는 감소하였다. Draft tube로 주입되는 기체 유속이 일정한 경우, annulus section으로 주입되는 기체 유속을 증가시킴에 따라 고체 입자의 순환속도 및 오리피스를 통한압력강하는 증가하였고, gas bypassing fractions는 기체 유속을 증가시킴에 따라 고체 입자의 순환속도 및 오리피스를 통한 압력강하는 증가하였고, gas bypassing fractions는 일정하였다. 실험결과, 사각 내부순환유동층에서의 수력학적 특성은 기존의 원형 내부순환 유동층의 수력학적 특성과 같은 경향을 보였다.