ISSN : 1225-0112(Print)
ISSN : 2288-4505(Online)
ISSN : 2288-4505(Online)
RESEARCH PAPERS : A Study on Poisoning of the Reforming Catalysts on the Position of Anode in the Direct Internal Reforming Molten Carbonate Fuel Cell
Abstract
The trend of poisoning of reforming catalyst along with the position of anodic catalyst bed was studied. Keeping the conditions that steam to carbon ratio was 2.5, operating voltage was 0.75V, current density was 140mA/cm2, the unit cell was operated during 24 hrs at a steady state. And then the cell was stopped, the catalysts packed in the position of inlet, middle and outlet were sampled individually and then the amount of carbon, Li and K poisoned were analysed. After 100 hrs operated, the catalysts at the same positions were analysed at the same manner. The result of this experiment was as followings. After 24 hrs operated, the poisoning amounts of Li and K in the catalyst were 0.27 wt% at inlet, 0.23 wt% at middle and the highest value 1.59 wt% at outlet. After 100 hrs, the amount of poisoning is the highest in the catalyst packed at the inlet of unit cell. The performance simulation of unit cell explained these trends of poisoning catalysts. The simulation told that the catalyst in the region of the inlet of unit cell treated the 90% of initial methane flow rate and the highest electrochemical reaction happened in this region. So the catalysts of this region were the most poisoned with carbon, Li and K and also the rateof poisoning is faster than that of the catalyst at other regions. The temperature at the region of outlet of unit cell was 30℃ higher than that of other regions, so more Li, and K vaporized than at other regions and little reforming reaction at this region made the catalysts poisoning rate low.
연구논문 : 직접 내부개질형 용융탄산염 연료전지의 음극판 위치에 따른 개질 촉매 피독에 관한 연구
초록
메탄을 연료로 한 직접 내부개질형 용융탄산염 연료전지의 anode전극위치에 따른 개질 촉매의 피독 현상을 규명하였다. 수증기-탄소 비를 2.5로 고정시킨 후 운전전압 0.75V, 전류밀도 140mA/cm2을 유지하면서 24시간 운전중인 연료전지를 정지시키고 anode전극 내, 가스흐름 방향으로 입구, 중간 및 출구 부분에 충전된 촉매를 채취하여 탄소와 전해질 성분인 리튬과 칼륨의 피독 정도를 분석하였고 운전시간 100시간 후, 같은 방법으로 촉매를 분석하였다. 그 결과, 운전시간 24시간 경과 후 촉매의 리튬과 칼륨의 피독량은 입구부에서 0.27 wt%, 중간부에서 0.23 wt% 출구부에서 1.59 wt%로 출구부에 충전된 촉매 피독량이 제일 높았지만 100시간 경과 후 촉매의 피독량은 입구부에서 가장 높았다. 이러한 결과는 직접 내부개질형 연료전지의 성능 모사를 통한 전극 내 위치별 반응속도와 이에 따른 촉매의 역할로 설명이 가능하였다. 전지의 성능 모사 결과 전극 내 메탄-수증기 개질 반응은 입구 부분 30%까지 초기 메탄 유입량의 90%가 반응하여 이 부분에 충전된 촉매가 가장 많이 사용되고 전극반응도 가장 활발하게 일어나 입구부 촉매의 탄소와 전해질 피독량이 높았고 운전 시간에 따른 피독 정도가 가장 빨랐다. 전극 내 출구부는 가장 높은 온도분포를 보이고 있어 상대적으로 전해질 증발이 많아져 운전 초기부터 촉매의 전해질 피독이 빠르게 일어나지만 개질 반응과 전극 반응은 상대적으로 적게 진행되어 촉매의 피독 속도는 크지 않았다.