The effect of variables on the current efficiency and cell voltage of indium electrowinning from chloride solution has been examined. Ionic equilibria for the InCl_(3)-HCl-NaOH-H_(2)O system at 25℃ were analyzed and the experimentally measured pH values agreed well withthose calculated from the analysis. The initial pH of electrolyte solution, reaction temperature and current density showed negligible effect on the current efficiency and cell voltage increased linearly with the current density. In order to achieve current efficiency of 90% at the current density of 100mA/cm^(2), the initial concentration of indium and NaCl should be higher than 50 g/L.

연구논문 : 염산용액에서 염화인듐의 이온평형 해석 및 전해채취에 의한 인듐의 고순도화

이만승,오영주

초록

염산용액에서 인듐의 전해채취 조건이 전류효율과 전해전압에 미치는 영향을 조사하였고, 전해액에 대한 이온평형을 해석하였다. InCl₃-HCI-NaOH-H₂O계의 이온평형을 해석하여 계산한 용액의 pH와 25℃에서 측정값은 서로 잘 일치하였다. 실험조건에서 전해액의 초기 pH, 전해반응 온도와 전류밀도는 전류효율에 거의 영향을 미치지 않았으나, 전해전압은 전류밀도에 대해 직선적으로 증가하였다. 전류밀도 100 mA/cm²의 조건에서 인듐과 NaCl의 농도는 모두 50 g/L 이상 유지되어야 90% 이상의 전류효율을 얻을 수 있었다.