Research Papers : Measurement of Oxygen Content in Liquid Sodium by a Plugging Temperature Indicator
Abstract
For the safe operation of the liquid metal reactor, it is very important to control the purity of sodium which is used as a coolant. A plugging temperature indicator (PTI) was fabricated to give a modified temperature control mode and it was studied on the measurement of the oxygen content in the liquid sodium. The PTI was operated with two modes- bare orifice mode and partially plugged mode. In the bare orifice mode, the difference between the plugging temperature and the saturated temperature was great and the plugging temperature was influenced by the cooling rate in the mode. Whereas, in the partially plugged mode, the difference was reduced significantly and the calibration of the PTI was not required since the operating parameters did not affect the determination of the plugging temperature. It was possible to save the measuring time by reducing the amplitude of the temperature oscillation.
연구논문 : 막힘온도 지시계를 이용한 액체 나트륨중의 산소 농도 측정
초록
액체금속로에서는 냉각재로 사용되는 나트륨의 순도관리가 매우 중요하다. 제어 방식이 개선된 막힘온도 지시계를 제작하고, 이를 이용하여 나트륨중의 불순물 농도를 측정하는 연구를 수행하였으며, 수동과 자동의 두 가지 방식으로 운전하였다. 수동모드에서는 막힘온도와 포화온도의 격차가 크고, 냉각속도에 따라 막힘온도의 값이 달라졌다. 자동모드에서는 막힘온도와 포화온도의 격차가 현저히 줄었고, 조업 변수의 영향을 거의 받지 않아서 조업조건의 변화에 따라 검정곡선을 매번 작성하지 않아도 되었다. 자동모드에서 오리피스 온도의 변화 진폭을 조절함으로써 조업시간의 단축이 가능하였다.