Abstract

Experiments on micro-leak of water were carried out with the water injecting simulator in liquid sodium atmosphere. The leak path was plugged by the sodium-water reaction products in the 2.25Cr-1Mo steel specimen. However, leak paths re-opened in most cases. The self-wastage patterns were not affected by the sodium temperature in the re-opened specimen. The diameter of the defected area, including the re-opened part, was about 5 min. It took 143, 40.7 and 34.7 minutes to re-open the leak path at 450, 475, and 510 ℃, respectively. It was concluded that the reopening time decreased with the increasing temperature.

연구논문 : Self - wastage 에 의한 2.25Cr-1Mo Steel 시편의 Reopen 현상

정경채,권상운

초록

누출시험 장치를 이용하여 미량 물 누출 실험을 수행하였다. 2.25Cr-1Mo 시편의 누출경로는 나트륨-물 반응 생성물에 의해 plugging되는 경우가 발생하였으나, 대부분 re-open상태를 나타내었다. 또한 누출 경로가 완전 re-open된 후 나트륨 부위에서 시편의 self-wastage pattern은 온도에 영향을 받지 않음을 알 수 있었으며, 누출경로가 re-open 되면서 나타나는 defected 크기는 대략 5 mm 이내임을 알 수 있었다. 누출 경로가 완전 re-open 되는데 걸리는 시간은나트륨 온도가 높을수록 짧게 나타났으며, 평균적으로 450 ℃에서 143분, 475 ℃ 의 경우 40.7분, 510 ℃의 경우 34.7분을 나타내었다.